10~35kV Cool Shrinkable Accessories
In the past over ten years,the quality of Yongjin product has owned a good reputation in the national power field.
Even in the beginning,Yongjin shrink product has a same step with world level.It's serving power industry with first-class quality and sreative design.
Yongjin Company has passed the certification of ISO9001:2000 quality System
Good Performance:
Adopt lately developed German organic silicone rubber;
With very strong electricity resistance cpapbility;
Long-term weatherability among corrosive;
Long-termhydrophobicity;
Excellent dielectric performance
Automatic reset:
Pull out prefabricated liner tube or draw prefabricated liner stripe out to make "shrink" atutomatically reset.
Stress control part and insulating part are both put colsely together with the main insulation body of cable and they "breathe " together with the main body of cable.
The product conforms to JB8144-95(IEC60502-97). |
 |
Easy installation:
The installation doesn't need fire and heating(without power source). After
Quality guarantee:
The company has passed ISO9001:2000 international quality system.
The certificate No.is 1003Q10647R1M |
 |
Wide uses:
One model is applicable to several kinds of diameters of cable;
The material maintains unchanged among the surroundings at-50¡æ~+100¡æ
Applicable to using in salt fog region,severe cold region,high-temperature and high damp region;
Suitable for many industries, such as power,petroleum,iron and steel, coal mine,railway and oil field,etc.
Model No.and specification:
1、Single-core cable terminal lectotype meter:
|
Voltage Grade |
Outdoor number |
Indoor number |
Conductor cut(mm2) |
|
8.7/15kV |
WYL 3101 |
NYL3101 |
25~50 |
|
WYL 3102 |
NYL3102 |
70~120 |
|
WYL 3103 |
NYL3103 |
150~240 |
|
WYL 3104 |
NYL3104 |
300~400 |
2、 Three-core cable terminal lectotype meter:
|
Voltage Grade |
Outdoor number |
Indoor number |
Conductor cut(mm2) |
|
8.7/15kV |
WYL 3301 |
NYL3301 |
25~50 |
|
WYL 3301-A |
NYL3301-A |
35~70 |
|
WYL 3302 |
NYL3302 |
95~150 |
|
WYL 3303 |
NYL3303 |
185~240 |
|
WYL 3304 |
NYL3304 |
300~400 |
3、Single-core Cable middle joint lectotype meter:
|
Voltage Grade |
Number |
Conductor cut(mm2) |
|
8.7/15kV |
JLSY-1201 |
25~50 |
|
JLSY-1202 |
70~120 |
|
JLSY-1203 |
150~240 |
|
JLSY-1204 |
300~400 |
|
26/35kV |
JLSY-5201 |
50~95 |
|
JLSY-5202 |
120~185 |
|
JLSY-5203 |
240~300 |
|
JLSY-5204 |
400~500 |
4、Three-core Cable middle joint lectotype meter:
|
Voltage Grade |
Number |
Conductor cut(mm2) |
|
8.7/15kV |
JLSY-3201 |
25~50 |
|
JLSY-3202 |
70~120 |
|
JLSY-3203 |
150~240 |
|
JLSY-3204 |
300~400 |
5、Single-core cable terminal lectotype meter:
|
Voltage Grade |
Outdoor number |
Indoor number |
Cable insulate Outside path (mm) |
Conductor cut(mm2) |
|
26/35kV |
WYL5101 |
NYL5101 |
27~38 |
50~185 |
|
WYL5102 |
NYL5102 |
37~50 |
240~500 |
6、Three-core cable terminal lectotype meter:
|
Voltage Grade |
Outdoor number |
Indoor number |
Cable insulate Outside path (mm) |
Conductor cut(mm2) |
|
26/35kV |
WYL5301 |
NYL5301 |
27~38 |
50~185 |
|
WYL5302 |
NYL5302 |
37~50 |
240~500 |
|
10-35kV,Three-core shrink outdoor termination |
|
10-35kV,Three-core shrink indoor termination |
|
|
10-35kV, Cable middle joint |
|